Abstract

The GlideScope® video laryngoscope (VL) provides direct visualization of the larynx in patients with a potentially difficult airway. A specialized rigid stylet or tracheal introducer should be used to guide the tip of the endotracheal tube (ETT) into the glottis while using the GlideScope® devices. Several studies showed the success of the GlideScope® VL. However, there have been reports of problems, complications, including failure to intubate patients successfully. Laryngeal exposure is generally the simple part of the procedure, and conversely, tube delivery to the glottic opening and advancement into the trachea is sometimes not straightforward. Alekberli–Yarmush technique: Our novel technique for improving the GlideScope® intubation's success requires preparation of the stylet and ETT before the intubation. Requirements are the following: any brand and model shapable ETT stylet, ETT, and lubricant. Firstly, lubricate the stylet with a lubricant, insert the stylet into ETT, and bend the stylet into a unique shape. Firstly bend the ETT into the two-dimensional circular C shape, then bend the tip again two-dimensionally, approximately 100–110° against the circular angle. For the final step, bend the tip toward the 3rd dimension medially, proximally 45°. Endotracheal tube insertion is usually performed in our method, as the manufacturer recommends a four-step insertion technique when using the GlideScope®. However, holding the tube with two fingers, palm up, 2/3 of the way down the tube toward the tip, is different from the traditional technique. To intubate using our novel technique, first, the GlideScope® should be introduced into the oropharynx's midline with the left hand. When the epiglottis is identified on the screen, the scope should be manipulated, and the tip of the blade should be put in vollecula and elevate the epiglottis to obtain the best view of the glottis. The ETT should then be guided into position under direct vision. The ETT should be hugging the undersurface of the tongue. When the distal tip of the ETT disappears from the direct view, it should be viewed on the monitor. In this time, rotation and angulation maneuvers are not required in our technique different than the traditional technique to direct the ETT through the glottis. After visualizing the successful intubation, a stylet should be pulled out to remove easily from the ETT. The unique shape of the novel technique described here can improve the GlideScope® intubation by decreasing the manipulation, rotation, and angulation maneuvers. Due to the medially 45° shaped tip of the ETT, the intubation may be smoother and more comfortable. The ETT's C type circular shape allows it to hug the tongue's undersurface and slide quickly and smoothly to the laryngeal space. Studies with larger patient populations are needed to determine if the new technique improves the GlideScope® intubation, better understand the mechanisms and the clinical significance, and ascertain whether this technique evolves into a useful technique.


HTML PDF Share
  1. Apfelbaum JL, Hagberg CA, Caplan RA, et al. American Society of Anesthesiologists task force on management of the difficult airway. Practice guidelines for management of the difficult airway: an updated report by the American Society of Anesthesiologists task force on management of the difficult airway. Anesthesiology 2013;118(2):251–270. DOI: 10.1097/ALN.0b013e31827773b2.
  2. Kaplan MB, Hagberg CA, Ward DS, et al. Comparison of direct and video-assisted views of the larynx during routine intubation. J Clin Anesth 2006;18(5):357–362. DOI: 10.1016/j.jclinane.2006.01.002.
  3. Cooper RM, Pacey JA, Bishop MJ, et al. Early clinical experience with a new videolaryngoscope (GlideScope) in 728 patients. Can J Anaesth 2005;52(2):191–198. DOI: 10.1007/BF03027728.
  4. Aziz MF, Dillman D, Fu R, et al. Comparative effectiveness of the C-MAC video laryngoscope versus direct laryngoscopy in the setting of the predicted difficult airway. Anesthesiology 2012;116(3):629–636. DOI: 10.1097/ALN.0b013e318246ea34.
  5. Jungbauer A, Schumann M, Brunkhorst V, et al. Expected difficult tracheal intubation: a prospective comparison of direct laryngoscopy and video laryngoscopy in 200 patients. Br J Anaesth 2009;102(4):546–550. DOI: 10.1093/bja/aep013.
  6. Teoh WH, Saxena S, Shah MK, et al. Comparison of three videolaryngoscopes: pentax airway scope, C-MAC, Glidescope vs the Macintosh laryngoscope for tracheal intubation. Anaesthesia 2010;65(11):1126–1132. DOI: 10.1111/j.1365-2044.2010.06513.x.
  7. Aziz MF, Healy D, Kheterpal S, et al. Routine clinical practice effectiveness of the Glidescope in difficult airway management: an analysis of 2,004 Glidescope intubations, complications, and failures from two institutions. Anesthesiology 2011;114(1):34–41. DOI: 10.1097/ALN.0b013e3182023eb7.
  8. Cavus E, Neumann T, Doerges V, et al. First clinical evaluation of the C-MAC D-Blade videolaryngoscope during routine and difficult intubation. Anesth Analg 2011;112(2):382–385. DOI: 10.1213/ANE.0b013e31820553fb.
  9. van Zundert A, Maassen R, Lee R, et al. A macintosh laryngoscope blade for videolaryngoscopy reduces stylet use in patients with normal airways. Anesth Analg 2009;109(3):825. DOI: 10.1213/ane.0b013e3181ae39db.
  10. Rai MR, Dering A, Verghese C. The GlideScope® system: a clinical assessment of performance. Anaesthesia 2005;60(1):60–64. DOI: 10.1111/j.1365-2044.2004.04013.x.
  11. GlideScope® GVL and Cobalt Quick Reference Guide. Bothwell, WA: Verathon Medical Inc; 2009-2011. pp. 30–31.
  12. Cooper RM. Use of a new videolaryngoscope (GlideScope®) in the management of a difficult airway. Can J Anaesth 2003;50(6):611–613. DOI: 10.1007/BF03018651.
  13. Sun DA, Warriner CB, Parsons DG, et al. The GlideScope® video laryngoscope: randomized clinical trial in 200 patients. Br J Anaesth 2005;94(3):381–384. DOI: 10.1093/bja/aei041.
  14. Marrel J, Blanc C, Frascarolo P, et al. Videolaryngoscopy improves intubation condition in morbidly obese patients. Eur J Anaesthesiol 2007;24(12):1045–1049. DOI: 10.1017/S0265021507000889.
  15. Alekberli T, Holger F, Mimouni C, et al. Indications for use of video laryngoscopy and flexible fiberoptic bronchoscopy for difficult airway management in a tertiary referral center. Eur J Anaesthesiol 2019;36(57):251.
  16. Curran C. Case report: oropharyngeal injuries with GlideScope® usage in two obese patients. Southern Afr J Anaesth Analge 2016;22(1):30–32. DOI: 10.1080/22201181.2015.1110403.
  17. Magboul MA, Shaw J. The video laryngoscopes’ blind spots and possible lingual nerve injury by the GlideRite® rigid stylet - case presentation and review of literature. Middle East J Anaesthesiol 2010;20(6):857–860.
  18. Rodney JD, Ahmed Z, Gupta D, et al. Straight to video: tonsillar injury during elective GlideScope® assisted intubation in a pediatric patient with adenotonsillar hypertrophy. Middle East J Anaesthesiol 2015;23(1):101–104.
  19. Malik AM, Frogel JK. Anterior tonsillar pillar perforation during GlideScope® video laryngoscopy. Anesth Analg 2007;104(6):1610–1611. DOI: 10.1213/01.ane.0000264321.04403.06.
  20. Levitan RM, Heitz JW, Sweeney M, et al. The complexities of tracheal intubation with direct laryngoscopy and alternative intubation devices. Ann Emerg Med 2011;57(3):240–247. DOI: 10.1016/j.annemergmed.2010.05.035.
PDF Share
PDF Share

© Jaypee Brothers Medical Publishers (P) LTD.